W 1500 S; Vanderfo over High Line Canal

Fair Condition62 years old200 vehicles/day

Location

StateIdaho
CountyBingham
Location2.5n. 2.0w.aberdeen;1500s
CarriesW 1500 S; Vanderfo
CrossesHigh Line Canal
Coordinates42.98050, -112.87725

Condition Ratings

Overall ConditionFair
Deck7 (Good)
Superstructure6 (Satisfactory)
Substructure7 (Good)
Channel/Waterway7 (Good)
Scour Critical8 — Stable, low risk

Physical Characteristics

MaterialPrestressed Concrete
DesignChannel Beam
Total Length39.0 ft (11.9 m)
Max Span37.1 ft (11.3 m)
Deck Width26.9 ft (8.2 m)
Deck Area97.6 sq m
Main Spans1
Year Built1964

Traffic

Avg Daily Traffic200 (2023)
Truck Traffic10%
Lanes On Bridge2

Inspection & Ownership

Last Inspection324
Inspection FrequencyEvery 24 months
OwnerCounty Highway Agency
Historical SignificanceHistorical significance is not determined
Structure Number000000000022730