N 2700 E over Crosscut Canal

Poor Condition89 years old10 vehicles/day

Location

StateIdaho
CountyFremont
Location1.7 S. 3.2 E. ST Anthony
CarriesN 2700 E
CrossesCrosscut Canal
Coordinates43.93642, -111.61833

Condition Ratings

Overall ConditionPoor
Deck8 (Very Good)
Superstructure6 (Satisfactory)
Substructure4 (Poor)
Channel/Waterway5 (Fair)
Scour Critical4 — Foundations need monitoring

Physical Characteristics

MaterialPrestressed Concrete
DesignTee Beam
Total Length34.1 ft (10.4 m)
Max Span33.1 ft (10.1 m)
Deck Width24.0 ft (7.3 m)
Deck Area75.9 sq m
Main Spans1
Year Built1937 (reconstructed 1974)

Traffic

Avg Daily Traffic10 (2023)
Truck Traffic10%
Lanes On Bridge2

Inspection & Ownership

Last InspectionOctober 2024
Inspection FrequencyEvery 12 months
OwnerCounty Highway Agency
Historical SignificanceHistorical significance is not determined
Structure Number000000000031850

Nearby Bridges