N 1500 E over St. Anthony Canal

Fair Condition66 years old70 vehicles/day

Location

StateIdaho
CountyFremont
Location0.8 N. 1.0 W. Egin
CarriesN 1500 E
CrossesSt. Anthony Canal
Coordinates43.94764, -111.85744

Condition Ratings

Overall ConditionFair
Deck6 (Satisfactory)
Superstructure6 (Satisfactory)
Substructure5 (Fair)
Channel/Waterway6 (Satisfactory)
Scour Critical8 — Stable, low risk

Physical Characteristics

MaterialPrestressed Concrete
DesignTee Beam
Total Length22.0 ft (6.7 m)
Max Span21.0 ft (6.4 m)
Deck Width24.3 ft (7.4 m)
Deck Area49.6 sq m
Main Spans1
Year Built1960

Traffic

Avg Daily Traffic70 (2023)
Truck Traffic10%
Lanes On Bridge2

Inspection & Ownership

Last InspectionNovember 2023
Inspection FrequencyEvery 24 months
OwnerCounty Highway Agency
Historical SignificanceHistorical significance is not determined
Structure Number000000000031995