I-90 Skyway over 71st ST
Fair Condition68 years old28,700 vehicles/day
Location
| State | Illinois |
| County | Cook |
| Location | 0.1 M E Cottage P7c |
| Carries | I-90 Skyway |
| Crosses | 71st ST |
| Coordinates | 41.76698, -87.60980 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 6 (Satisfactory) |
| Superstructure | 7 (Good) |
| Substructure | 6 (Satisfactory) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 106.0 ft (32.3 m) |
| Max Span | 97.4 ft (29.7 m) |
| Deck Width | 118.4 ft (36.1 m) |
| Deck Area | 1166.0 sq m |
| Main Spans | 1 |
| Year Built | 1958 (reconstructed 1994) |
Traffic
| Avg Daily Traffic | 28,700 (2020) |
| Truck Traffic | 16% |
| Lanes On Bridge | 6 |
| Lanes Under Bridge | 2 |
Inspection & Ownership
| Last Inspection | 822 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 016630200000000 |