I-90 Skyway over Ground SE Comm AVE
Fair Condition68 years old28,700 vehicles/day
Location
| State | Illinois |
| County | Cook |
| Location | 0.06 M SE Comm Av |
| Carries | I-90 Skyway |
| Crosses | Ground SE Comm AVE |
| Coordinates | 41.72469, -87.55096 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 6 (Satisfactory) |
| Superstructure | 6 (Satisfactory) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 467.2 ft (142.4 m) |
| Max Span | 114.8 ft (35 m) |
| Deck Width | 83.0 ft (25.3 m) |
| Deck Area | 3602.7 sq m |
| Main Spans | 4 |
| Year Built | 1958 (reconstructed 2003) |
Traffic
| Avg Daily Traffic | 28,700 (2020) |
| Truck Traffic | 16% |
| Lanes On Bridge | 6 |
Inspection & Ownership
| Last Inspection | 823 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 016641400000000 |