O&m Traffic over Main Outlet Drain Extens
Fair Condition60 years old20 vehicles/day
Location
| State | Arizona |
| County | Yuma |
| Location | 1 Mile E/o Pacific AVE |
| Carries | O&m Traffic |
| Crosses | Main Outlet Drain Extens |
| Coordinates | 32.71747, -114.58158 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 5 (Fair) |
| Superstructure | 5 (Fair) |
| Substructure | 7 (Good) |
| Channel/Waterway | 7 (Good) |
| Scour Critical | 8 — Stable, low risk |
Physical Characteristics
| Material | Prestressed Concrete |
| Design | Box Beam - Multiple |
| Total Length | 37.4 ft (11.4 m) |
| Max Span | 36.1 ft (11 m) |
| Deck Width | 17.1 ft (5.2 m) |
| Deck Area | 59.3 sq m |
| Main Spans | 1 |
| Year Built | 1966 |
Traffic
| Avg Daily Traffic | 20 (2012) |
| Lanes On Bridge | 2 |
Inspection & Ownership
| Last Inspection | 224 |
| Inspection Frequency | Every 24 months |
| Owner | Bureau of Reclamation |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 0304-0009 |