I-96 EB over Coit AVE
Fair Condition64 years old23,263 vehicles/day
Location
| State | Michigan |
| County | Kent |
| Location | In Grand Rapids |
| Carries | I-96 EB |
| Crosses | Coit AVE |
| Coordinates | 43.02101, -85.65471 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 7 (Good) |
| Superstructure | 5 (Fair) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 149.6 ft (45.6 m) |
| Max Span | 64.6 ft (19.7 m) |
| Deck Width | 47.2 ft (14.4 m) |
| Deck Area | 656.6 sq m |
| Main Spans | 3 |
| Year Built | 1962 |
Traffic
| Avg Daily Traffic | 23,263 (2015) |
| Truck Traffic | 8% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 2 |
Inspection & Ownership
| Last Inspection | 724 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 000000000004730 |