Victor DR over Small Wash

Good Condition45 years old220 vehicles/day

Location

StateArizona
CountyPima
LocationS Of Valencia RD
CarriesVictor DR
CrossesSmall Wash
Coordinates32.13167, -111.12333

Condition Ratings

Overall ConditionGood
Channel/Waterway8 (Very Good)
Culvert7 (Good)
Scour Critical8 — Stable, low risk

Physical Characteristics

MaterialConcrete Continuous
DesignCulvert
Total Length25.9 ft (7.9 m)
Max Span7.9 ft (2.4 m)
Deck Area71.9 sq m
Main Spans3
Year Built1981

Traffic

Avg Daily Traffic220 (2021)
Truck Traffic2%
Lanes On Bridge2

Inspection & Ownership

Last InspectionNovember 2023
Inspection FrequencyEvery 48 months
OwnerCounty Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number11604