Site 3 Bldg. 815 T over Drainage Ditch

Good Condition32 years old10 vehicles/day

Location

StateArizona
CountyPima
LocationSite 3 Tank Farm East Acc
CarriesSite 3 Bldg. 815 T
CrossesDrainage Ditch
Coordinates32.09997, -110.94364

Condition Ratings

Overall ConditionGood
Deck7 (Good)
Superstructure7 (Good)
Substructure7 (Good)
Channel/Waterway7 (Good)
Scour Critical8 — Stable, low risk

Physical Characteristics

MaterialConcrete Continuous
DesignFrame
Total Length33.8 ft (10.3 m)
Max Span9.8 ft (3 m)
Deck Width20.0 ft (6.1 m)
Deck Area62.8 sq m
Main Spans3
Year Built1994

Traffic

Avg Daily Traffic10 (2017)
Lanes On Bridge2

Inspection & Ownership

Last InspectionNovember 2023
Inspection FrequencyEvery 24 months
OwnerAir Force
Historical SignificanceBridge is not eligible for the National Register
Structure NumberAF49ACHA0001312

Nearby Bridges