Rmp EB Smrln-us95n over Us95
Good Condition20 years old38,000 vehicles/day
Location
| State | Nevada |
| County | Clark |
| Location | Las Vegas |
| Carries | Rmp EB Smrln-us95n |
| Crosses | Us95 |
| Coordinates | 36.17716, -115.24393 |
Condition Ratings
| Overall Condition | Good |
| Deck | 8 (Very Good) |
| Superstructure | 8 (Very Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 420.6 ft (128.2 m) |
| Max Span | 154.2 ft (47 m) |
| Deck Width | 30.5 ft (9.3 m) |
| Deck Area | 1192.3 sq m |
| Main Spans | 3 |
| Year Built | 2006 |
Traffic
| Avg Daily Traffic | 38,000 (2021) |
| Truck Traffic | 2% |
| Lanes On Bridge | 1 |
| Lanes Under Bridge | 10 |
Inspection & Ownership
| Last Inspection | December 2023 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | I1210R |