I790 SB over Csx Trans/amtrak Ny Sus
Fair Condition36 years old8,174 vehicles/day
Location
| State | New York |
| County | Oneida |
| Location | Jct SH 5 & SH 5s |
| Carries | I790 SB |
| Crosses | Csx Trans/amtrak Ny Sus |
| Coordinates | 43.10839, -75.23916 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 8 (Very Good) |
| Superstructure | 8 (Very Good) |
| Substructure | 6 (Satisfactory) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel Continuous |
| Design | Stringer/Multi-beam |
| Total Length | 261.2 ft (79.6 m) |
| Max Span | 128.0 ft (39 m) |
| Deck Width | 37.1 ft (11.3 m) |
| Deck Area | 899.5 sq m |
| Main Spans | 2 |
| Year Built | 1990 |
Traffic
| Avg Daily Traffic | 8,174 (2017) |
| Truck Traffic | 6% |
| Lanes On Bridge | 2 |
Inspection & Ownership
| Last Inspection | October 2024 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 000000001073850 |