Ramp 2c over SR 2
Good Condition60 years old1,677 vehicles/day
Location
| State | Ohio |
| County | Ottawa |
| Location | Jct. SR 2c And SR 2/sr 53 |
| Carries | Ramp 2c |
| Crosses | SR 2 |
| Coordinates | 41.51218, -82.90523 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel Continuous |
| Design | Stringer/Multi-beam |
| Total Length | 283.1 ft (86.3 m) |
| Max Span | 87.9 ft (26.8 m) |
| Deck Width | 49.9 ft (15.2 m) |
| Deck Area | 1311.8 sq m |
| Main Spans | 4 |
| Year Built | 1966 |
Traffic
| Avg Daily Traffic | 1,677 (2018) |
| Truck Traffic | 3% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 4 |
Inspection & Ownership
| Last Inspection | 823 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 6200818 |