Interstate 80 over Potrero AVE & S80 On Rmp
Good Condition70 years old179,000 vehicles/day
Location
| State | California |
| County | Contra Costa |
| Location | 04-cc-080-1.67-ecr |
| Carries | Interstate 80 |
| Crosses | Potrero AVE & S80 On Rmp |
| Coordinates | 37.92064, -122.31749 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 292.0 ft (89 m) |
| Max Span | 113.8 ft (34.7 m) |
| Deck Width | 133.2 ft (40.6 m) |
| Deck Area | 3613.4 sq m |
| Main Spans | 4 |
| Year Built | 1956 (reconstructed 1997) |
Traffic
| Avg Daily Traffic | 179,000 (2019) |
| Truck Traffic | 3% |
| Lanes On Bridge | 8 |
| Lanes Under Bridge | 4 |
Inspection & Ownership
| Last Inspection | 623 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 28 0034 |