Monitor Street over Arvin-edison Canal

Fair Condition24 years old5,000 vehicles/day

Location

StateCalifornia
CountyKern
LocationS Of Ivy Trae Lane
CarriesMonitor Street
CrossesArvin-edison Canal
Coordinates35.29227, -119.01181

Condition Ratings

Overall ConditionFair
Deck6 (Satisfactory)
Superstructure7 (Good)
Substructure7 (Good)
Channel/Waterway8 (Very Good)
Scour Critical8 — Stable, low risk

Physical Characteristics

MaterialConcrete
DesignTee Beam
Total Length50.9 ft (15.5 m)
Max Span50.9 ft (15.5 m)
Deck Width69.9 ft (21.3 m)
Deck Area330.1 sq m
Main Spans1
Year Built2002

Traffic

Avg Daily Traffic5,000 (2014)
Truck Traffic3%
Lanes On Bridge3

Inspection & Ownership

Last InspectionDecember 2022
Inspection FrequencyEvery 48 months
OwnerCity/Municipal Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number50C0336