SR 1 SB over Calleguas Creek

Fair Condition92 years old4,300 vehicles/day

Location

StateCalifornia
CountyVentura
Location07-ven-001-9.87
CarriesSR 1 SB
CrossesCalleguas Creek
Coordinates34.11240, -119.08190

Condition Ratings

Overall ConditionFair
Deck7 (Good)
Superstructure7 (Good)
Substructure5 (Fair)
Channel/Waterway8 (Very Good)
Scour Critical5 — Stable for scour

Physical Characteristics

MaterialConcrete
DesignTee Beam
Total Length240.2 ft (73.2 m)
Max Span29.9 ft (9.1 m)
Deck Width37.4 ft (11.4 m)
Deck Area834.5 sq m
Main Spans8
Year Built1934

Traffic

Avg Daily Traffic4,300 (2020)
Truck Traffic4%
Lanes On Bridge2

Inspection & Ownership

Last Inspection124
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number52 0010L