Pgbt (sh190) Dc02 over Ih30 Wbfr & Pgbt Nbfr
Good Condition14 years old4,300 vehicles/day
Location
| State | Texas |
| County | Dallas |
| Location | Ih30 / Pgbt Interchange |
| Carries | Pgbt (sh190) Dc02 |
| Crosses | Ih30 Wbfr & Pgbt Nbfr |
| Coordinates | 32.86096, -96.54923 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel Continuous |
| Design | Box Beam - Multiple |
| Total Length | 2336.9 ft (712.3 m) |
| Max Span | 163.1 ft (49.7 m) |
| Deck Width | 27.9 ft (8.5 m) |
| Deck Area | 6054.6 sq m |
| Main Spans | 2 |
| Year Built | 2012 |
Traffic
| Avg Daily Traffic | 4,300 (2012) |
| Truck Traffic | 5% |
| Lanes On Bridge | 1 |
| Lanes Under Bridge | 9 |
Inspection & Ownership
| Last Inspection | 424 |
| Inspection Frequency | Every 24 months |
| Owner | Local Toll Authority |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 180570000911459 |