Ih35e Sb/pgbt WB over IH 35e Sbfr
Good Condition22 years old10,000 vehicles/day
Location
| State | Texas |
| County | Dallas |
| Location | IH 35e/sh 190 Interchange |
| Carries | Ih35e Sb/pgbt WB |
| Crosses | IH 35e Sbfr |
| Coordinates | 32.98162, -96.93327 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete |
| Design | Stringer/Multi-beam |
| Total Length | 1932.1 ft (588.9 m) |
| Max Span | 125.0 ft (38.1 m) |
| Deck Width | 38.1 ft (11.6 m) |
| Deck Area | 6831.2 sq m |
| Main Spans | 14 |
| Year Built | 2004 |
Traffic
| Avg Daily Traffic | 10,000 (2011) |
| Truck Traffic | 2% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 2 |
Inspection & Ownership
| Last Inspection | 424 |
| Inspection Frequency | Every 48 months |
| Owner | Local Toll Authority |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 180570019603455 |