Us-191 (sr-191) over Flaming Gorge Dam Splway
Fair Condition62 years old1,715 vehicles/day
Location
| State | Utah |
| County | Daggett |
| Location | Flaming Gorge Dam |
| Carries | Us-191 (sr-191) |
| Crosses | Flaming Gorge Dam Splway |
| Coordinates | 40.91468, -109.41988 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 6 (Satisfactory) |
| Superstructure | 6 (Satisfactory) |
| Substructure | 6 (Satisfactory) |
| Channel/Waterway | 8 (Very Good) |
| Scour Critical | 8 — Stable, low risk |
Physical Characteristics
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 618.4 ft (188.5 m) |
| Max Span | 47.9 ft (14.6 m) |
| Deck Width | 29.9 ft (9.1 m) |
| Deck Area | 1715.3 sq m |
| Main Spans | 1 |
| Year Built | 1964 |
Traffic
| Avg Daily Traffic | 1,715 (2014) |
| Truck Traffic | 41% |
| Lanes On Bridge | 2 |
Inspection & Ownership
| Last Inspection | 723 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is eligible for the National Register |
| Structure Number | 0C 724 |