S15-w60 Connector over W60-milliken Av Off-ramp
Fair Condition47 years old23,000 vehicles/day
Location
| State | California |
| County | Riverside |
| Location | 08-riv-015-51.54-cor |
| Carries | S15-w60 Connector |
| Crosses | W60-milliken Av Off-ramp |
| Coordinates | 34.02379, -117.55510 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 5 (Fair) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 458.0 ft (139.6 m) |
| Max Span | 80.1 ft (24.4 m) |
| Deck Width | 42.0 ft (12.8 m) |
| Deck Area | 1786.9 sq m |
| Main Spans | 7 |
| Year Built | 1979 |
Traffic
| Avg Daily Traffic | 23,000 (2017) |
| Truck Traffic | 1% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 1 |
Inspection & Ownership
| Last Inspection | 624 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 56 0686F |