Wire Mountain RD over Interstate 5
Poor Condition59 years old17,900 vehicles/day
Location
| State | California |
| County | San Diego |
| Location | 11-sd-005-r54.79-ocn |
| Carries | Wire Mountain RD |
| Crosses | Interstate 5 |
| Coordinates | 33.21566, -117.39043 |
Condition Ratings
| Overall Condition | Poor |
| Deck | 4 (Poor) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 214.9 ft (65.5 m) |
| Max Span | 107.0 ft (32.6 m) |
| Deck Width | 34.1 ft (10.4 m) |
| Deck Area | 681.2 sq m |
| Main Spans | 2 |
| Year Built | 1967 |
Traffic
| Avg Daily Traffic | 17,900 (2020) |
| Truck Traffic | 2% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 8 |
Inspection & Ownership
| Last Inspection | 424 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 57 0580 |