Interstate 8 EB over Victoria DR

Good Condition57 years old17,000 vehicles/day

Location

StateCalifornia
CountySan Diego
Location11-sd-008-r30.17
CarriesInterstate 8 EB
CrossesVictoria DR
Coordinates32.83508, -116.75124

Condition Ratings

Overall ConditionGood
Deck7 (Good)
Superstructure7 (Good)
Substructure7 (Good)
Scour CriticalNot applicable

Physical Characteristics

MaterialConcrete Continuous
DesignTee Beam
Total Length128.0 ft (39 m)
Max Span44.0 ft (13.4 m)
Deck Width58.7 ft (17.9 m)
Deck Area698.1 sq m
Main Spans3
Year Built1969 (reconstructed 2002)

Traffic

Avg Daily Traffic17,000 (2014)
Truck Traffic7%
Lanes On Bridge3
Lanes Under Bridge2

Inspection & Ownership

Last Inspection124
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number57 0600R

Nearby Bridges