Cook Overcrossing over Route 5
Fair Condition38 years old1,200 vehicles/day
Location
| State | California |
| County | San Diego |
| Location | 11-sd-005-r58.53-ocn |
| Carries | Cook Overcrossing |
| Crosses | Route 5 |
| Coordinates | 33.25631, -117.42577 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 5 (Fair) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 473.1 ft (144.2 m) |
| Max Span | 166.0 ft (50.6 m) |
| Deck Width | 32.8 ft (10 m) |
| Deck Area | 1,442 sq m |
| Main Spans | 3 |
| Year Built | 1988 |
Traffic
| Avg Daily Traffic | 1,200 (2020) |
| Truck Traffic | 2% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 8 |
Inspection & Ownership
| Last Inspection | 224 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 57 0977 |