Harding ST over Escondido Creek
Good Condition38 years old5,600 vehicles/day
Location
| State | California |
| County | San Diego |
| Location | 0.1 Mi N Valley Parkway |
| Carries | Harding ST |
| Crosses | Escondido Creek |
| Coordinates | 33.13318, -117.06435 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Channel/Waterway | 9 (Excellent) |
| Scour Critical | 8 — Stable, low risk |
Physical Characteristics
| Material | Prestressed Concrete |
| Design | Stringer/Multi-beam |
| Total Length | 85.0 ft (25.9 m) |
| Max Span | 81.0 ft (24.7 m) |
| Deck Width | 76.1 ft (23.2 m) |
| Deck Area | 600.9 sq m |
| Main Spans | 1 |
| Year Built | 1988 |
Traffic
| Avg Daily Traffic | 5,600 (2020) |
| Truck Traffic | 1% |
| Lanes On Bridge | 4 |
Inspection & Ownership
| Last Inspection | 322 |
| Inspection Frequency | Every 48 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 57C0592 |