Fdr 504 over Cabin Canyon

Fair Condition89 years old27 vehicles/day

Location

StateColorado
CountyDolores
Location8.2 Mi On Fdr 504
CarriesFdr 504
CrossesCabin Canyon
Coordinates37.63334, -108.69696

Condition Ratings

Overall ConditionFair
Deck5 (Fair)
Superstructure7 (Good)
Substructure6 (Satisfactory)
Channel/Waterway8 (Very Good)
Scour Critical4 — Foundations need monitoring

Physical Characteristics

MaterialSteel
DesignStringer/Multi-beam
Total Length41.0 ft (12.5 m)
Max Span36.1 ft (11 m)
Deck Width24.3 ft (7.4 m)
Deck Area92.5 sq m
Main Spans1
Year Built1937 (reconstructed 1960)

Traffic

Avg Daily Traffic27 (2003)
Lanes On Bridge2

Inspection & Ownership

Last Inspection723
Inspection FrequencyEvery 24 months
OwnerU.S. Forest Service
Historical SignificanceHistorical significance is not determined
Structure Number021301000001140