Interlocken Loop S over W. Flatiron Crossing
Good Condition26 years old6,609 vehicles/day
Location
| State | Colorado |
| County | Broomfield |
| Location | 400 Ft N. Of Interlocken |
| Carries | Interlocken Loop S |
| Crosses | W. Flatiron Crossing |
| Coordinates | 39.93053, -105.12792 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 8 (Very Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Stringer/Multi-beam |
| Total Length | 153.9 ft (46.9 m) |
| Max Span | 71.9 ft (21.9 m) |
| Deck Width | 47.9 ft (14.6 m) |
| Deck Area | 684.7 sq m |
| Main Spans | 2 |
| Year Built | 2000 |
Traffic
| Avg Daily Traffic | 6,609 (2023) |
| Truck Traffic | 5% |
| Lanes On Bridge | 3 |
| Lanes Under Bridge | 7 |
Inspection & Ownership
| Last Inspection | 125 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | BFD-INTLW-W.FLT |