I110 Sr8a SB over I110 Sr8a & I10 Sr8
Fair Condition21 years old43,250 vehicles/day
Location
| State | Florida |
| County | Escambia |
| Location | I110 SB Ramp (ramp G) |
| Carries | I110 Sr8a SB |
| Crosses | I110 Sr8a & I10 Sr8 |
| Coordinates | 30.50347, -87.23044 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 6 (Satisfactory) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete |
| Design | Stringer/Multi-beam |
| Total Length | 287.1 ft (87.5 m) |
| Max Span | 146.3 ft (44.6 m) |
| Deck Width | 43.0 ft (13.1 m) |
| Deck Area | 1146.2 sq m |
| Main Spans | 2 |
| Year Built | 2005 |
Traffic
| Avg Daily Traffic | 43,250 (2022) |
| Truck Traffic | 6% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 9 |
Inspection & Ownership
| Last Inspection | 624 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 480199 |