US 1 SB (900016) over Big Spanish Channel

Fair Condition54 years old6,850 vehicles/day

Location

StateFlorida
CountyMonroe
LocationBahia Honda Key (mm 36.0)
CarriesUS 1 SB (900016)
CrossesBig Spanish Channel
Coordinates24.65839, -81.28639

Condition Ratings

Overall ConditionFair
Deck6 (Satisfactory)
Superstructure5 (Fair)
Substructure5 (Fair)
Channel/Waterway7 (Good)
Scour Critical5 — Stable for scour

Physical Characteristics

MaterialPrestressed Concrete
DesignStringer/Multi-beam
Total Length6733.9 ft (2052.5 m)
Max Span102.0 ft (31.1 m)
Deck Width42.3 ft (12.9 m)
Deck Area26477.2 sq m
Main Spans78
Year Built1972

Traffic

Avg Daily Traffic6,850 (2024)
Truck Traffic14%
Lanes On Bridge2

Inspection & Ownership

Last Inspection924
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number900016