Ramp To Linden Pl over Whitestone Expressway SE
Fair Condition19 years old9,000 vehicles/day
Location
| State | New York |
| County | Queens |
| Location | Flushing River |
| Carries | Ramp To Linden Pl |
| Crosses | Whitestone Expressway SE |
| Coordinates | 40.76456, -73.83972 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 6 (Satisfactory) |
| Superstructure | 7 (Good) |
| Substructure | 6 (Satisfactory) |
| Channel/Waterway | 8 (Very Good) |
| Scour Critical | 5 — Stable for scour |
Physical Characteristics
| Material | Steel Continuous |
| Design | Box Beam - Single/Spread |
| Total Length | 1006.9 ft (306.9 m) |
| Max Span | 307.1 ft (93.6 m) |
| Deck Width | 24.6 ft (7.5 m) |
| Deck Area | 2301.8 sq m |
| Main Spans | 3 |
| Year Built | 2007 |
Traffic
| Avg Daily Traffic | 9,000 (2012) |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 5 |
Inspection & Ownership
| Last Inspection | 924 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 000000001055916 |