SR 12 over Agua Caliente Creek

Fair Condition102 years old18,600 vehicles/day

Location

StateCalifornia
CountySonoma
Location04-son-012-35.75
CarriesSR 12
CrossesAgua Caliente Creek
Coordinates38.30539, -122.47772

Condition Ratings

Overall ConditionFair
Deck7 (Good)
Superstructure7 (Good)
Substructure6 (Satisfactory)
Channel/Waterway5 (Fair)
Scour Critical7 — Countermeasures installed

Physical Characteristics

MaterialConcrete
DesignTee Beam
Total Length30.8 ft (9.4 m)
Max Span27.9 ft (8.5 m)
Deck Width47.2 ft (14.4 m)
Deck Area135.4 sq m
Main Spans1
Year Built1924 (reconstructed 1970)

Traffic

Avg Daily Traffic18,600 (2014)
Lanes On Bridge2

Inspection & Ownership

Last Inspection924
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number20 0024