Fessenden ST over Burlington Northern R&r

Poor Condition117 years old4,931 vehicles/day

Location

StateOregon
CountyMultnomah
LocationFessenden St. Over Burlin
CarriesFessenden ST
CrossesBurlington Northern R&r
Coordinates45.59190, -122.72910

Condition Ratings

Overall ConditionPoor
Deck4 (Poor)
Superstructure4 (Poor)
Substructure6 (Satisfactory)
Scour CriticalNot applicable

Physical Characteristics

MaterialSteel
DesignTruss - Deck
Total Length164.0 ft (50 m)
Max Span89.9 ft (27.4 m)
Deck Width60.0 ft (18.3 m)
Deck Area915 sq m
Main Spans1
Year Built1909

Traffic

Avg Daily Traffic4,931 (2010)
Truck Traffic10%
Lanes On Bridge2

Inspection & Ownership

Last Inspection724
Inspection FrequencyEvery 24 months
OwnerRailroad
Historical SignificanceBridge is eligible for the National Register
Structure Number51T104000000000