Atlantic-s710 Onrp over La Junction Ry
Good Condition69 years old6,424 vehicles/day
Location
| State | California |
| County | Los Angeles |
| Location | 07-la-710-21.79-bell |
| Carries | Atlantic-s710 Onrp |
| Crosses | La Junction Ry |
| Coordinates | 33.99562, -118.17753 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 8 (Very Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Concrete Continuous |
| Design | Tee Beam |
| Total Length | 110.9 ft (33.8 m) |
| Max Span | 43.0 ft (13.1 m) |
| Deck Width | 31.5 ft (9.6 m) |
| Deck Area | 324.5 sq m |
| Main Spans | 3 |
| Year Built | 1957 |
Traffic
| Avg Daily Traffic | 6,424 (2022) |
| Truck Traffic | 8% |
| Lanes On Bridge | 2 |
Inspection & Ownership
| Last Inspection | 724 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 53 0839K |