S110-n&s5 Connectr over ST RTE 110 & Arroyo Seco

Good Condition64 years old15,201 vehicles/day

Location

StateCalifornia
CountyLos Angeles
Location07-la-110-26.12-la
CarriesS110-n&s5 Connectr
CrossesST RTE 110 & Arroyo Seco
Coordinates34.08526, -118.21871

Condition Ratings

Overall ConditionGood
Deck7 (Good)
Superstructure7 (Good)
Substructure7 (Good)
Scour CriticalNot applicable

Physical Characteristics

MaterialPrestressed Concrete
DesignTee Beam
Total Length694.9 ft (211.8 m)
Max Span123.0 ft (37.5 m)
Deck Width34.1 ft (10.4 m)
Deck Area2202.7 sq m
Main Spans5
Year Built1962

Traffic

Avg Daily Traffic15,201 (2020)
Truck Traffic2%
Lanes On Bridge2
Lanes Under Bridge2

Inspection & Ownership

Last InspectionOctober 2024
Inspection FrequencyEvery 48 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register