W134-s2 Connector over RTE 2 Broadway Colorado

Good Condition50 years old15,273 vehicles/day

Location

StateCalifornia
CountyLos Angeles
Location07-la-134-r9.04-la
CarriesW134-s2 Connector
CrossesRTE 2 Broadway Colorado
Coordinates34.14252, -118.22794

Condition Ratings

Overall ConditionGood
Deck7 (Good)
Superstructure7 (Good)
Substructure7 (Good)
Scour CriticalNot applicable

Physical Characteristics

MaterialPrestressed Concrete Continuous
DesignBox Beam - Multiple
Total Length1431.4 ft (436.3 m)
Max Span180.1 ft (54.9 m)
Deck Width34.1 ft (10.4 m)
Deck Area4537.5 sq m
Main Spans3
Year Built1976

Traffic

Avg Daily Traffic15,273 (2020)
Truck Traffic2%
Lanes On Bridge2
Lanes Under Bridge24

Inspection & Ownership

Last InspectionNovember 2023
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Structure Number53 1917F

Nearby Bridges