Imperial-s110 Onrp over S110-w105 Connector Ramp
Good Condition39 years old14,700 vehicles/day
Location
| State | California |
| County | Los Angeles |
| Location | 07-la-110-13.89-la |
| Carries | Imperial-s110 Onrp |
| Crosses | S110-w105 Connector Ramp |
| Coordinates | 33.93004, -118.28154 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 282.2 ft (86 m) |
| Max Span | 125.0 ft (38.1 m) |
| Deck Width | 35.4 ft (10.8 m) |
| Deck Area | 928.8 sq m |
| Main Spans | 3 |
| Year Built | 1987 |
Traffic
| Avg Daily Traffic | 14,700 (2022) |
| Truck Traffic | 1% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 2 |
Inspection & Ownership
| Last Inspection | 524 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 53 2683K |