Willow ST over Edison Access RD Uc
Good Condition64 years old28,620 vehicles/day
Location
| State | California |
| County | Los Angeles |
| Location | 0.3mi W/o I-605 FWY |
| Carries | Willow ST |
| Crosses | Edison Access RD Uc |
| Coordinates | 33.80410, -118.08871 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Concrete |
| Design | Slab |
| Total Length | 44.0 ft (13.4 m) |
| Max Span | 40.0 ft (12.2 m) |
| Deck Width | 74.5 ft (22.7 m) |
| Deck Area | 304.2 sq m |
| Main Spans | 1 |
| Year Built | 1962 |
Traffic
| Avg Daily Traffic | 28,620 (2014) |
| Truck Traffic | 2% |
| Lanes On Bridge | 4 |
Inspection & Ownership
| Last Inspection | October 2024 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 53C0282 |