Interstate 40 over Tank Tower Ditch
Poor Condition55 years old7,450 vehicles/day
Location
| State | California |
| County | San Bernardino |
| Location | 08-sbd-040-r119.50 |
| Carries | Interstate 40 |
| Crosses | Tank Tower Ditch |
| Coordinates | 34.84311, -114.97819 |
Condition Ratings
| Overall Condition | Poor |
| Deck | 5 (Fair) |
| Superstructure | 5 (Fair) |
| Substructure | 4 (Poor) |
| Channel/Waterway | 4 (Poor) |
| Scour Critical | 3 — Scour critical |
Physical Characteristics
| Material | Concrete Continuous |
| Design | Slab |
| Total Length | 81.0 ft (24.7 m) |
| Max Span | 32.2 ft (9.8 m) |
| Deck Width | 41.0 ft (12.5 m) |
| Deck Area | 308.8 sq m |
| Main Spans | 3 |
| Year Built | 1971 |
Traffic
| Avg Daily Traffic | 7,450 (2019) |
| Truck Traffic | 40% |
| Lanes On Bridge | 2 |
Inspection & Ownership
| Last Inspection | 323 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 54 0202L |