E-470 SB over Quincy Avenue
Good Condition29 years old22,768 vehicles/day
Location
| State | Colorado |
| County | Arapahoe |
| Location | 13.31 Mi From I25 |
| Carries | E-470 SB |
| Crosses | Quincy Avenue |
| Coordinates | 39.63816, -104.71922 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Stringer/Multi-beam |
| Total Length | 219.5 ft (66.9 m) |
| Max Span | 106.6 ft (32.5 m) |
| Deck Width | 74.1 ft (22.6 m) |
| Deck Area | 1511.9 sq m |
| Main Spans | 2 |
| Year Built | 1997 (reconstructed 2017) |
Traffic
| Avg Daily Traffic | 22,768 (2018) |
| Truck Traffic | 6% |
| Lanes On Bridge | 3 |
| Lanes Under Bridge | 6 |
Inspection & Ownership
| Last Inspection | 724 |
| Inspection Frequency | Every 24 months |
| Owner | Local Toll Authority |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | E-470-13.31B |