Sr618a Selmon Expy over 12th ST To 26th ST
Fair Condition20 years old7,300 vehicles/day
Location
| State | Florida |
| County | Hillsborough |
| Location | 1.7mi W/o 50th ST (us-41) |
| Carries | Sr618a Selmon Expy |
| Crosses | 12th ST To 26th ST |
| Coordinates | 27.95554, -82.44694 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 7 (Good) |
| Superstructure | 6 (Satisfactory) |
| Substructure | 6 (Satisfactory) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Prestressed Concrete Continuous |
| Design | Segmental Box Girder |
| Total Length | 6841.9 ft (2085.4 m) |
| Max Span | 155.8 ft (47.5 m) |
| Deck Width | 60.0 ft (18.3 m) |
| Deck Area | 38162.8 sq m |
| Main Spans | 50 |
| Year Built | 2006 |
Traffic
| Avg Daily Traffic | 7,300 (2024) |
| Truck Traffic | 1% |
| Lanes On Bridge | 3 |
| Lanes Under Bridge | 23 |
Inspection & Ownership
| Last Inspection | 824 |
| Inspection Frequency | Every 24 months |
| Owner | State Toll Authority |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 100800 |