Fsr 200 over Unnamed Stream

Poor Condition50 years old50 vehicles/day

Location

StateFlorida
CountyBaker
Location1.75 Mi West Of State 250
CarriesFsr 200
CrossesUnnamed Stream
Coordinates30.42626, -82.32578

Condition Ratings

Overall ConditionPoor
Deck5 (Fair)
Superstructure4 (Poor)
Substructure4 (Poor)
Channel/Waterway4 (Poor)
Scour Critical5 — Stable for scour

Physical Characteristics

MaterialSteel Continuous
DesignGirder and Floorbeam
Total Length32.2 ft (9.8 m)
Max Span29.9 ft (9.1 m)
Deck Width17.1 ft (5.2 m)
Deck Area51.0 sq m
Main Spans1
Year Built1976

Traffic

Avg Daily Traffic50
Lanes On Bridge1

Inspection & Ownership

Last Inspection124
Inspection FrequencyEvery 24 months
OwnerU.S. Forest Service
Historical SignificanceHistorical significance is not determined
Structure Number080504000029135