Fsr 200 over Unnamed Stream

Fair Condition50 years old20 vehicles/day

Location

StateFlorida
CountyBaker
Location9.25 Mi West Of State 250
CarriesFsr 200
CrossesUnnamed Stream
Coordinates30.42844, -82.35355

Condition Ratings

Overall ConditionFair
Deck6 (Satisfactory)
Superstructure5 (Fair)
Substructure5 (Fair)
Channel/Waterway7 (Good)
Scour Critical5 — Stable for scour

Physical Characteristics

MaterialSteel Continuous
DesignGirder and Floorbeam
Total Length46.9 ft (14.3 m)
Max Span44.9 ft (13.7 m)
Deck Width17.1 ft (5.2 m)
Deck Area74.4 sq m
Main Spans2
Year Built1976

Traffic

Avg Daily Traffic20
Lanes On Bridge1

Inspection & Ownership

Last Inspection124
Inspection FrequencyEvery 24 months
OwnerU.S. Forest Service
Historical SignificanceHistorical significance is not determined
Structure Number080504000029137