Is 95 Viaduct NB over Boston ST Odonnell S
Good Condition46 years old57,722 vehicles/day
Location
| State | Maryland |
| County | Baltimore |
| Location | 1.6 Mi N Of Toll Facility |
| Carries | Is 95 Viaduct NB |
| Crosses | Boston ST Odonnell S |
| Coordinates | 39.27560, -76.55184 |
Condition Ratings
| Overall Condition | Good |
| Deck | 7 (Good) |
| Superstructure | 7 (Good) |
| Substructure | 7 (Good) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel Continuous |
| Design | Stringer/Multi-beam |
| Total Length | 2504.9 ft (763.5 m) |
| Max Span | 195.9 ft (59.7 m) |
| Deck Width | 62.0 ft (18.9 m) |
| Deck Area | 14430.1 sq m |
| Main Spans | 18 |
| Year Built | 1980 |
Traffic
| Avg Daily Traffic | 57,722 (2019) |
| Truck Traffic | 11% |
| Lanes On Bridge | 3 |
| Lanes Under Bridge | 14 |
Inspection & Ownership
| Last Inspection | October 2023 |
| Inspection Frequency | Every 24 months |
| Owner | State Toll Authority |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 300000BCW576011 |