I-696 Ramp EB over I-75 & Ramps To I-75 NB
Fair Condition55 years old5,100 vehicles/day
Location
| State | Michigan |
| County | Oakland |
| Location | @i-75 |
| Carries | I-696 Ramp EB |
| Crosses | I-75 & Ramps To I-75 NB |
| Coordinates | 42.47717, -83.11147 |
Condition Ratings
| Overall Condition | Fair |
| Deck | 5 (Fair) |
| Superstructure | 6 (Satisfactory) |
| Substructure | 6 (Satisfactory) |
| Scour Critical | Not applicable |
Physical Characteristics
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 321.9 ft (98.1 m) |
| Max Span | 137.1 ft (41.8 m) |
| Deck Width | 29.5 ft (9 m) |
| Deck Area | 882.9 sq m |
| Main Spans | 4 |
| Year Built | 1971 (reconstructed 2007) |
Traffic
| Avg Daily Traffic | 5,100 (1982) |
| Truck Traffic | 5% |
| Lanes On Bridge | 1 |
| Lanes Under Bridge | 6 |
Inspection & Ownership
| Last Inspection | 723 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Structure Number | 000000000007979 |